Getting Started
DKIT-04 Dimmer Starter Kit
Simply Automated, Incorporated
Pre-Configured Input 1: Low voltage input. Turns on first dimmer (#16) when trigger is enabled.
Turns off first dimmer when trigger is disabled. Used for delay entry/exit (lights on for entry, off
for exit), arm/disarm acknowledgement, door strike or motion sensor interface. Installer needs to
program security panel for each trigger interface. Low voltage wires (provide 0 Volt ‘off‘ or 4-5
Volt ‘on’ trigger) from security panel connect to input terminals 6/7 of the I/O Module.
Pre-Configured Input 2: Low voltage or contact closure input. Turns on both lights and flashes
when triggered is enabled. Turns off lights and stops flashing dimmers when trigger is disabled.
Used for fire, intrusion or panic alarms. Installer needs to program security panel for alarm type
and trigger. Low voltage wires (provide 0 Volt ‘off’ or 4-5 Volt ‘on’ trigger) from security panel
connect to input terminals 8/9, or contact closure wires (provide open – ‘off’ or closed – ‘on’
trigger) connect to input terminals 9/10 of the I/O module.
Pre-Configured Input 3: Low voltage or contact closure input. Turns on both lights when trigger is
enabled. Turns off both lights when trigger is disabled. Used for fire, intrusion or panic alarms.
Installer needs to program security panel for alarm type and trigger. Low voltage wires (provide 0
Volt ‘off’ or 4-5 Volt ‘on’ trigger) from security panel connect to input terminals 14/15, or contact
closure wires (provide open – ‘off’ or closed – ‘on’ trigger) connect to input terminals 15/16 of the
I/O Module.
Testing the I/O Module and 2 dimmers:
• Input 1: Apply a low voltage source (i.e., 9V DC battery) to input terminals 6/7 of the I/O
Module to turn on first dimmer (#16). Disconnect battery or press (tap) the bottom rocker of
dimmer to turn off.
• Input 2: Apply a low voltage source (i.e., 9V DC battery) to input terminals 8/9 of the I/O
Module to flash both dimmers. For contact closure, apply input (i.e., short circuit with #18
wire) to input terminals 9/10 of the I/O Module. Remove low voltage source, or contact
closure source to turn off both dimmers.
• Input 3: Apply a low voltage source (i.e., 9V DC battery) to input terminals 14/15 of the I/O
Module to turn on both dimmers. For contact closure, apply input (e.g. short circuit with #18
wire) to input terminals 15/16 of the I/O Module. Remove the low-voltage or contact closure
source to turn off both dimmers.
Important Note: You will hear a soft buzz when the I/O Module is transmitting a signal to the
dimmers. If you hear a buzz, but the controlled dimmers do not turn on/off, see Section 5, Phase
Coupler.